| Code |
VSI-XXWXXX-DF1/DF2/ DF4 |
VSI-XXWXXX-DF1 |
| Input |
Input Power |
8-13W |
13-25W |
25-35W |
35-45W |
| Input Voltage |
180-264V |
| Rated Input Voltage(V) |
200-240V |
| Frequency |
50Hz |
| Input Current |
≤0.08A |
≤0.14A |
≤0.2A |
≤0.25A |
| Rated Input Current |
≤0.07A |
≤0.13A |
≤0.18A |
≤0.23 A |
| Power Factor (typ) |
0.9 |
| Total Harmonic |
<20% @230V |
| Distortion(THD) |
| Efficiency (typ) |
≥80% |
≥83% |
≥84% |
≥84% |
| Inrush Current (Typ.) |
2.67A/76uS |
2.18A/135uS |
3.06A/224uS |
4.64A/224uS |
| Max Circuit Breaker |
Please refer to" Circuit breaker Specification" |
| Leakage Current |
<0.5mA/240V |
| No Load Wattage |
<0.5w @230V |
| Output |
Output Voltage Range |
30-40V |
| Rated Output Current |
180-300mA |
300-600mA |
600-800mA |
800-1050mA |
| Line Regulation |
±5% |
| Open Circuit Voltage (max) |
50V |
| Setup time(note1) |
500ms @230V |
| Flickering Index(IEEEStd 1789) |
5%(LOW RISK) |
4%(LOW RISK) |
3%(LOW RISK) |
| Protection |
Short Circuit Protection |
Constant current limiting recovers automatically after the fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage |
| Over Temperature Protection |
Shut down o/p voltage, recovers automatically after temperature goes down |
| Safety&EMC |
Safety Standards |
IEC/EN61347-1, IEC/EN61347-2-13, IEC/EN62384 independent,GB19510.14,GB19510.1 approved |
| Withstand Voltage |
I/P-O/P:3.75KVac,<5mA 60S |
| Isolation Resistance |
I/P-O/P: 500VDC, ≥100M Ω |
| Surge |
IEC/EN61000-4-5(L-N:0.5KV) |
IEC/EN61000-4-5(L-N:1KV) |
| EMC Emission |
IEC/EN55015, IEC/EN61000-3-2 |
| EMC Immunity |
IEC/EN61000-4-2,3,4,5,6,8,11; IEC/EN61547 |
| Other |
Dimension |
93*37*26mm(L*W*H) |
118*44*26mm(L*W*H) |
138*47*26mm(L*W*H) |
153*52*30mm(L*W*H) |
| Weight |
0.105Kg |
0.200Kg |
0.235Kg |
0.340Kg |