| Code |
VMI-XXWXXXX-N1 |
| Input |
Input Power |
8-10W |
12-15W |
16-20W |
22-35W |
36-45W |
| Input Voltage |
AC90-305V |
| Rated Input Voltage(V) |
AC100-277V |
| Frequency |
50/60HZ |
| Input Current |
≤0.13A |
≤0.19A |
≤0.25A |
≤0.44A |
≤0.56A |
| Rated Input Current |
≤0.12A |
≤0.17A |
≤0.23A |
≤0.39A |
≤0.5A |
| Power Factor (typ) |
0.9 |
| Total Harmonic Distortion(THD) |
<20% @230V |
| Efficiency (typ) |
82% |
82% |
85% |
87% |
87% |
| Inrush Current (Typ.) |
19.4A/32.7uS |
18.6A/31.7uS |
26.3A/30.8uS |
44A/7.32uS |
48.2A/26.3uS |
| Max Circuit Breaker |
Please refer to" Circuit breaker Specification" |
| Leakage Current |
<0.5mA/100-277V |
| No Load Wattage |
<0.5w @100-277V |
| Output |
Output Voltage Range |
30-40V |
| Rated Output Current |
180-250mA |
300-350mA |
400-500mA |
550-850mA |
900-1100mA |
| Line Regulation |
±5% |
| Open Circuit Voltage (max) |
50V |
| Setup time(note1) |
<1s @120V,<0.5s @230V |
| Protection |
Short Circuit Protection |
Constant current limiting, recovers automatically after fault condition is removed |
| Over Voltage Protection |
Shut down o/p voltage |
| Over Temperature Protection |
Shut down o/p voltage, recovers automatically after temperature goes down |
| Environment |
Ambient temperature range ta |
-20…+60 °C |
| Maximum case temperature tc |
85°C (Measured on tc point indicated of the product label, tc not exceeded) |
| Operating temperature |
-20…+60 °C |
| Storage temperature/humidity |
-25…+85 °C; 5-95% RH |
| Relative humidity |
5…85% |
| Environmental rating |
Indoor |
| IP rating |
IP20 |
| Life time |
>50,000H @25°C |
| Safety&EMC |
Safety Standards |
IEC/EN61347-1, IEC/EN61347-2-13, IEC/EN62384 independent,GB19510.14,GB19510.1 approved |
| Withstand Voltage |
I/P-O/P:3.75KVac,<5mA 60S |
| Isolation Resistance |
I/P-O/P: 500VDC, ≥100M Ω |
| Surge |
IEC/EN61000-4-5(L-N:0.5KV ) |
IEC/EN61000-4-5(L-N:1KV ) |
| Other |
Dimension |
93*27*26mm(L*W*H) |
118*44*26mm(L*W*H) |
| Weight |
0.051Kg |
0.051Kg |
0.058Kg |
0.086Kg |
0.101Kg |